Digital multimeter The Fluke 107 Digital Multimeter adapts to your way of working! Thanks to its special shape, it fits comfortably in the palm of your hand, so you can easily use it in any working conditions. Accuracy Specifications AC voltage (40-500 Hz)1 Range Permission Error 6,000 V 60.00 V 600.0 V 0.001 V 0.01 V 0.1 V 1.0% + 3 DC voltage in volts 6,000 V 60.00 V 600.0 V 0.001 V 0.01V 0.1V 0.5% + 3 AC voltage (millivolts) 600.0 mV 0.1 mV 3.0% + 3 Diode test2 2,000 V 0.001 V 10% Resistance (ohm) 400.0 ohm 4,000 kOhm 40.00 kOhm 40.00 kOhm 4,000 MΩ 40.00 MΩ 0.1...Digital multimeter
The Fluke 107 Digital Multimeter adapts to your way of working! Thanks to its special shape, it fits comfortably in the palm of your hand, so you can easily use it in any working conditions.Accuracy Specifications | ||||
AC voltage (40-500 Hz)1 | Range | Permission | Error | |
6,000 V 60.00 V 600.0 V | 0.001 V 0.01 V 0.1 V | 1.0% + 3 | ||
DC voltage in volts | 6,000 V 60.00 V 600.0 V | 0.001 V 0.01V 0.1V | 0.5% + 3 | |
AC voltage (millivolts) | 600.0 mV | 0.1 mV | 3.0% + 3 | |
Diode test2 | 2,000 V | 0.001 V | 10% | |
Resistance (ohm) | 400.0 ohm 4,000 kOhm 40.00 kOhm 40.00 kOhm 4,000 MΩ 40.00 MΩ | 0.1 ohm 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ | 0.5% + 3 0.5% + 2 0.5% + 2 0.5% + 2 0.5% + 2 1.5% + 3 | |
Capacity3 | 50.00 nF 500.0 nF 5,000 uF 50.00uF 500.0uF 1000uF | 0.01 nF 0.1 nF 0.001uF 0.01uF 0.1uF 1 uF | 2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 | |
Frequency 4 Hz (10-100 kHz) | 50.00 Hz 500.0 Hz 5,000 kHz 50.00 kHz 100.0 kHz | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | 0.1% + 3 | |
Duty Cycle4 | 1% to 99% | 0.10% | Typically 1%5 | |
Alternating current (40-200Hz) | 4,000 A 10.00 A | 0.001 A 0.01A | 1.5% + 3 | |
D.C | 4,000 A 10.00 A | 0.001 A 0.01 A | 1.5% + 3 | |
| ||||
Function | Overload protection | Input impedance (nominal) | Common mode rejection ratio | Normal mode noise rejection factor |
AC voltage | 600 V1 | >10 MΩ <100 pF2 | >60 dB at DC, 50Hz or 60Hz | ? |
AC voltage (millivolts) | 600 mV | >1M, <100pF | > 80 dB at 50 Hz or 60 Hz | ? |
DC voltage in volts | 600 V1 | >10 MΩ <100 pF | >100 dB at DC, 50Hz or 60Hz | > 60 dB at 50 Hz or 60 Hz |
| ||||
General characteristics | ||||
Maximum voltage between any terminal and ground potential | 600 V | |||
LCD display | 6000 counts, update rate - 3/s | |||
Battery type | 2 AAA, NEDA 24 A, IEC LR03 | |||
Battery life | Minimum 200 hours | |||
Temperature | ||||
Operating conditionsWorking | 0 °C to 40 °C | |||
Storage: | -30 °C to +60 °C | |||
Relative Humidity | ||||
Operating Humidity | No condensation if <10°C ≥90% at 10–30°C; ?75% at 30-40°C | |||
Operating humidity, in the range of 40 MΩ | ≥80% at 10–30°C; ?70% at 30-40°C | |||
Height above sea level | ||||
Operating conditionsWorking | 2000 m | |||
Storage: | 12000 m | |||
Temperature coefficient | 0.1 X (normalized error) / °C ( 28 °C) | |||
Fuse protection for current inputs | 11A 1000V FAST Fuse, Fluke Specified Part Only | |||
Dimensions (L x W x H) | 142mm x 69mm x 28mm | |||
Weight | 200 g | |||
Degree of protection | IEC 60529: IP 40 | |||
Safety | IEC 61010-1: 600 V CAT III, pollution degree 2 | |||
Field of electromagnetic radiation | IEC 61326-1: Portable | |||
Electromagnetic compatibility | Applies to use in Korea only. Class A equipment (industrial transmission and communication equipment)1 | |||
1 This device complies with the requirements for industrial (class A) electromagnetic wave equipment, and sellers and users should pay attention to it. This equipment is not intended for domestic use, commercial use only. |
Product code 58749129