Insulation Tester, Fluke 1550C - Fluke
Insulation resistance meter Insulation testing up to 10 kV The 1555 and redesigned Fluke 1550C insulation resistance meters offer insulation testing up to 10 kV, making them ideal for testing a wide range of high voltage equipment including switchgears, motors, generators and cables. Now Fluke Insulation Testers can conduct the full range of test voltages specified in IEEE 43-2000 with a best-in-class, 3-year warranty and a CAT IV 600 V safety rating. With measurement storage and a PC interface, the 1555 and 1550C are ideal tools for preventive or predictive maintenance programs designed to identify potential equipment failures before...Insulation resistance meter
Insulation testing up to 10 kV
The 1555 and redesigned Fluke 1550C insulation resistance meters offer insulation testing up to 10 kV, making them ideal for testing a wide range of high voltage equipment including switchgears, motors, generators and cables. Now Fluke Insulation Testers can conduct the full range of test voltages specified in IEEE 43-2000 with a best-in-class, 3-year warranty and a CAT IV 600 V safety rating. With measurement storage and a PC interface, the 1555 and 1550C are ideal tools for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur.
Electrical characteristics
The error of the tester is normalized within one year after calibration in the operating temperature range from 0 °C to 35 °C. For operating temperatures outside the specified range (-20°C to 0°C and 35°C to 50°C), add ±0.25% per °C, within 20% of range add ±1% per °C
Test voltage | Range | Accuracy (± readings) |
250 V | < 200 kOhm from 200 kΩ to 5 GΩ 5 GΩ to 50 GΩ > 50 Gom | not standardized 5 % 20 % not standardized |
500 V | < 200 kOhm from 200 kΩ to 10 GΩ from 10 GΩ to 100 GΩ > 100 GΩ | not standardized 5 % 20 % not standardized |
1000 V | < 200 kOhm from 200 kΩ to 20 GΩ from 20 GΩ to 200 GΩ > 200 GΩ | not standardized 5 % 20 % not standardized |
2500 V | < 200 kOhm from 200 kΩ to 50 GΩ from 50 GΩ to 500 GΩ > 500 GΩ | not standardized 5 % 20 % not standardized |
5000 V | < 200 kOhm from 200 kΩ to 100 GΩ from 100 GΩ to 1 TΩ > 1 TOM | not standardized 5 % 20 % not standardized |
10000 V (1555 only) | < 200 kOhm from 200 kΩ to 200 GΩ from 200 GΩ to 2 TΩ > 2 TOM | not standardized 5 % 20 % not standardized |
Histogram range | from 0 to 1 TOM |
Test voltage error | -0%, +10% at 1mA load current |
Suppression of induced current from the network | Maximum 2 mA |
Charge rate for capacitive load | 5 seconds per uF |
Discharge rate for capacitive load | 1.5 s/uF |
Range | Error | |
Leakage current measurement | 1 nA to 2 mA | ±(5% + 2nA) |
Capacitance measurement | 0.01 uF to 15.00 uF | ± (15% of reading + 0.03 uF) |
Timer | Range 0 to 99 minutes | Permission Setpoint: 1 minute Indication: 1 second |
Live Circuit Warning | Warning range 30 V to 660 V AC/DC, 50/60 Hz | Voltage error ±(15% + 2V) |
General characteristics | |||
Display |
| ||
Nutrition |
| ||
Charger Input (Variable) |
| ||
This Class II (double insulated) appliance is supplied with a Class 1 (grounded) power cord. The protective earth pin is not connected internally. The additional output is only used to connect the plug. | |||
Dimensions |
| ||
Weight |
| ||
Temperature (working) |
| ||
Temperature (storage) |
| ||
Humidity |
| ||
Height |
| ||
Case protection degree |
| ||
Input overload protection |
| ||
Electromagnetic compatibility |
| ||
Certification | |||
Security category |
| ||
Degree of pollution |
|
Product code 58749134
brand Fluke
State Новое
Manufacturer country США