Article number: 58749134

Insulation Tester, Fluke 1550C - Fluke

Insulation resistance meter Insulation testing up to 10 kV The 1555 and redesigned Fluke 1550C insulation resistance meters offer insulation testing up to 10 kV, making them ideal for testing a wide range of high voltage equipment including switchgears, motors, generators and cables. Now Fluke Insulation Testers can conduct the full range of test voltages specified in IEEE 43-2000 with a best-in-class, 3-year warranty and a CAT IV 600 V safety rating. With measurement storage and a PC interface, the 1555 and 1550C are ideal tools for preventive or predictive maintenance programs designed to identify potential equipment failures before...

Insulation resistance meter

Insulation testing up to 10 kV

The 1555 and redesigned Fluke 1550C insulation resistance meters offer insulation testing up to 10 kV, making them ideal for testing a wide range of high voltage equipment including switchgears, motors, generators and cables. Now Fluke Insulation Testers can conduct the full range of test voltages specified in IEEE 43-2000 with a best-in-class, 3-year warranty and a CAT IV 600 V safety rating. With measurement storage and a PC interface, the 1555 and 1550C are ideal tools for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur.

Electrical characteristics

The error of the tester is normalized within one year after calibration in the operating temperature range from 0 °C to 35 °C. For operating temperatures outside the specified range (-20°C to 0°C and 35°C to 50°C), add ±0.25% per °C, within 20% of range add ±1% per °C

Test voltage Range Accuracy (± readings)
250 V < 200 kOhm
from 200 kΩ to 5 GΩ
5 GΩ to 50 GΩ
> 50 Gom
not standardized
5 %
20 %
not standardized
500 V < 200 kOhm
from 200 kΩ to 10 GΩ
from 10 GΩ to 100 GΩ
> 100 GΩ
not standardized
5 %
20 %
not standardized
1000 V < 200 kOhm
from 200 kΩ to 20 GΩ
from 20 GΩ to 200 GΩ
> 200 GΩ
not standardized
5 %
20 %
not standardized
2500 V < 200 kOhm
from 200 kΩ to 50 GΩ
from 50 GΩ to 500 GΩ
> 500 GΩ
not standardized
5 %
20 %
not standardized
5000 V < 200 kOhm
from 200 kΩ to 100 GΩ
from 100 GΩ to 1 TΩ
> 1 TOM
not standardized
5 %
20 %
not standardized
10000 V
(1555 only)
< 200 kOhm
from 200 kΩ to 200 GΩ
from 200 GΩ to 2 TΩ
> 2 TOM
not standardized
5 %
20 %
not standardized
Histogram range from 0 to 1 TOM
Test voltage error -0%, +10% at 1mA load current
Suppression of induced current from the network Maximum 2 mA
Charge rate for capacitive load 5 seconds per uF
Discharge rate for capacitive load 1.5 s/uF
Range Error
Leakage current measurement 1 nA to 2 mA ±(5% + 2nA)
Capacitance measurement 0.01 uF to 15.00 uF ± (15% of reading + 0.03 uF)
Timer Range
0 to 99 minutes
Permission
Setpoint: 1 minute
Indication: 1 second
Live Circuit Warning Warning range
30 V to 660 V AC/DC, 50/60 Hz
Voltage error
±(15% + 2V)

General characteristics
Display
75mm x 105mm
Nutrition
Lead-acid battery 12 V, Yuasa NP2.8-12
Charger Input (Variable)
85 - 250 VAC e.g. 50/60 Hz 20 VA
This Class II (double insulated) appliance is supplied with a Class 1 (grounded) power cord. The protective earth pin is not connected internally. The additional output is only used to connect the plug.
Dimensions
170mm x 242mm x 330mm (6.7" x 9.5" x 13")
Weight
3.6 kg (7.94 lb)
Temperature (working)
-20 ?C to 50 ?C (-4 ?F to 122 ?F)
Temperature (storage)
-20 ?C to 65 ?C (-4 ?F to 149 ?F)
Humidity
80% to 31°C, decreases linearly to 50% at 50°C
Height
2000 m
Case protection degree
IP40
Input overload protection
1000 V AC
Electromagnetic compatibility
EN 61326
Certification
Security category
CAT III 1000 V, CAT IV 600 V
Degree of pollution
2

Product code 58749134

brand Fluke

State Новое

Manufacturer country США

Leave a request