Industrial meter for demanding users.
New diagnostic data for maximum factory performance. The new 289 is a new generation of high performance industrial cutting multimeter designed to solve complex problems in electronics, automation, power distribution systems and electromechanical equipment. With the ability to log data and then graphically display it on the screen, you can resolve problems faster and minimize downtime. Let the new 289 be your watchdog for systems or processes while you're away from solving other problems.
Be sure to also check out the Fluke 287 True-RMS Electronics Logging Multimeter with TrendCapture option designed for electronics professionals.
Maximum performance with the combined Fluke 289 and FlukeView Combo Kit forms. With a built-in data logger and TrendCapture option capability, 289 helps you track down subtle, intermittent problems, monitoring equipment with any of its features while doing other jobs. Overlay your logged data from six meters or six time periods to find cause and effect relationships or for condition monitoring applications in the FVF software. Turn your data into meaningful graphs and tables for a professional report. The 289/FVF combo set gives you a practical and affordable approach to preventive maintenance.
Specifications |
DC voltage | Error | 0.025% | Range and Resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
|
AC voltage | Error | 0.4%(True RMS) | Range and Resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
|
D.C | Error | 0.15% | Range and resolution | 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
|
Alternating current | Error | 0.7% (True RMS) | Range and resolution | 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
|
Temperature (excluding probe) | Error | 1.0% | Range and resolution | - 200.0°C to 1090.0°C (-328.0°F to 1994.0°F) |
|
Resistance | Error | 0.05% | Range and resolution | 50.000Ω, 500.00Ω, 5.0000kΩ, 50.000kΩ, 500.00kΩ, 5.0000MΩ, 50.00MΩ, 500.0MΩ |
|
Resistance 10 50 ohm (two-wire connection) | Error | 0.15% + 20 | Range and resolution | 50000 ohm |
|
Capacity | Error | 1.0% | Range and resolution | 1.000nF, 10.00nF 100.0nF, 1.000uF, 10.00uF, 100.0uF, 1000uF, 10.00mF, 100.00mF Ohm |
|
Frequency | Error | 0.005% + 1 | Range and resolution | 999.99 kHz |
|
Additional features/features | Simultaneous display of several readings on the display | Yes | True RMS AC bandwidth | 100 kHz | dBV/dBm | Yes | mV DC resolution | 1 uV | Resistance range in MΩ | Up to 500M | Conductivity | 50.00 nS | Sound signal to check the continuity of the circuit | Yes | Temperature (°C and °F) | 200°C - 1090°C | Battery/Access to fuses | Battery / Fuse | Peak values | 250 µS | Hours of used time | Yes | daytime hours | Yes | Min-Max-Avg. | Yes | Frequency | Yes | Fill factor | 0.01% to 99.99% | Pulse Width | 0.025ms, 0.25ms, 2.5ms, 1250.0ms | Retention | Yes | Interface with optocoupler | Yes | Auto/Touch HOLD | Yes | Reading memory | Yes | Registration on PC | Yes | Interval/Event Logging | Yes | Recording memory | Up to 10,000 readings | Low resistance range | 0.001 ohm to 50.000 ohm with 10 mA current source | loz | Yes | Low pass filter | Yes |
|