Pliers True RMS 600A AC/DC current, Fluke 375/E - Fluke

Clamp meters With the ability to measure true rms AC current and voltage, the Fluke-375 can display values up to 600V and 600A in both AC and DC mode, and can also measure frequencies up to 500Hz. In addition, the Fluke-375 is compatible with the new iFlex Flexible Current Probe (sold separately), which extends the measurement range to 2500 A AC. Compliance with the requirements of safety standards EN/IEC 61010-1:2001; 1000V CAT III, 600V CAT IV Features and Benefits Measuring range 500 mV DC for connection of additional equipment Built-in low-pass filter and state-of-the-art signal processing allows the instrument to be...

Clamp meters

  • With the ability to measure true rms AC current and voltage, the Fluke-375 can display values up to 600V and 600A in both AC and DC mode, and can also measure frequencies up to 500Hz.
  • In addition, the Fluke-375 is compatible with the new iFlex Flexible Current Probe (sold separately), which extends the measurement range to 2500 A AC.
  • Compliance with the requirements of safety standards EN/IEC 61010-1:2001; 1000V CAT III, 600V CAT IV

Features and Benefits

  • Measuring range 500 mV DC for connection of additional equipment
  • Built-in low-pass filter and state-of-the-art signal processing allows the instrument to be used in environments with strong electrical noise and provide stable readings
  • Patented inrush measurement technology filters out noise and measures motor inrush current exactly as it is sensed by circuit protection
  • Ergonomic design fits well in the hand and can be used while wearing protective equipment
  • The large, easy-to-read backlit display automatically sets the correct measuring range, so there is no need to change the switch position while taking measurements
  • Soft carrying case

Specifications

Electrical characteristics

Alternating current Range 600.0 A
Resolution 0.1 A
Accuracy 2% ±5 digits (10 - 100 Hz); 2.5% ±5 digits (100 - 500 Hz);
Form factor (50/60 Hz) 3 at 500 A +2% for aspect ratio > 2
AC (via iFlex™) Range 2500 A
Resolution 0.1 A (? 600 A); 1 A (? 2500 A)
Accuracy 3% ±5 digits (5 - 500 Hz)
Form factor (50/60 Hz) 3.3 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
+2% for aspect ratio > 2
D.C Range 600.0 A
Resolution 0.1A
Accuracy 2% ±5 digits
AC voltage Range 600.0 V
Resolution 0.1V
Accuracy 1% ±5 digits (20 - 500 Hz)
DC voltage Range 600.0 V
Resolution 0.1V
Accuracy 1% ±5 digits
Resistance Range 600.0 ohms / 6000 ohms / 60 k ohms
Resolution 0.1 ohm / 1 ohm / 10 ohm
Accuracy 1% ±5 digits
Integrity ? 30 ohm
Capacity Range 1.0 - 100.0 uF / 1000 uF
Resolution 0.1uF / 1uF
Accuracy 1% ±4 digits
Frequency Range 5.0 - 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 - 10 Hz (?10 A), 10 - 100 Hz (?5 A), 100 - 500 Hz (?10 A)
Frequency with flexible current probe Range 5.0 - 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 - 20 Hz (?25 A), 20 - 100 Hz (?20 A), 100 - 500 Hz (?25 A)
Nonlinear loads True RMS (True RMS)
Measurement of starting throws Yes

Main characteristics

Measured conductor diameter 34 mm
Flexible current probe diameter 7.5mm
Flexible current probe cable length 1.8 m
Dimensions, LxWxH 248 x 85 x 45mm
Weight 375 g
Nutrition 2 AA batteries

terms of Use

Operating temperature range -10°C to +50°C (14°F to 122°F)
Storage temperature -40°C to +60°C (-40°F to 140°F)
Relative Humidity Non-condensing (<10°C) ?90% (10 - 30 ?C) ?75% (30 - 40 ?C) ?45% (40 - 50 ?C)
Working in dimly lit areas Backlight
Working Altitude 3000 m
Safety standards CAN/CSA-C22.2 No. 61010-1-04
ANSI/UL 61010-1:2004
ANSI/ISA-61010-1(82.02.01):2004
EN/IEC 61010-1:2001 up to 1000 V measurement category (CAT) III, 600 V measurement category (CAT) IV
Pollution degree 2
EN/IEC 61010-2-032:2002
EN/IEC 61010-031:2002+A1:2008
EMI Immunity, EMC EMI, EMC
EN61326-1:2006
Temperature coefficient 0.1% °C ( 28 °C)
Guarantee 3 years

Model Differences

Characteristic Fluke-381 Fluke-376 Fluke-375 Fluke-374 Fluke-373 Fluke-365
Coverage 34 mm 34 mm 34 mm 34 mm 34 mm 18 mm

Alternating current
Range 999.9 A 999.9 A 600.0 A 600.0 A 600.0 A 200.0 A
Burial ±(2%+5) ±(2%+5) ±(2%+5) ±(2%+5) ±(2%+5) ±(2%+5)
iFlex Flexible Current Sensor Included Included Compatible Compatible - -
AC (iFlex) Range 2500 A 2500 A 2500 A 2500 A - -
Burial ±(3%+5) ±(3%+5) ±(3%+5) ±(3%+5) - -
D.C Range 999.9 A 999.9 A 600.0 A 600.0 A - 200.0 A
Burial ±(2%+5) ±(2%+5) ±(2%+5) ±(2%+5) - ±(2%+5)
AC voltage Range 1000 V 1000 V 600 V 600 V 600 V 600 V
Burial ±(1%+5) ±(1%+5) ±(1%+5) ±(1%+5) ±(1%+5) ±(1%+5)
Constant pressure Range 1000 V 1000 V 600 V 600 V 600 V 600 V
Burial ±(1%+5) ±(1%+5) ±(1%+5) ±(1%+5) ±(1%+5) ±(1%+5)
mV range e.g. - 500 mV 500 mV - - -
Resistance Range 60 kOhm 60 kOhm 60 kOhm 6 kOhm 6 kOhm 6 kOhm
Burial ±(1%+5) ±(1%+5) ±(1%+5) ±(1%+5) ±(1%+5) ±(1%+5)
Capacity Range - 1...1000 uF 1...1000 uF 1...1000 uF 10...1000 uF -
Burial - ±(1%+4) ±(1%+4) ±(1%+4) ±(1.9%+2) -
Integrity <30 ohm <30 ohm <30 ohm <30 ohm <30 ohm <30 ohm
Frequency 5...500 Hz 5...500 Hz 5...500 Hz - -
Removable display + - - - - -
Reaction to alternating current True RMS True RMS True RMS True RMS True RMS True RMS
Backlight + + + + + +
Hold readings + + + + + +
Min/Max/Avg + + + + - -
starting throw + + + + - -
Category CATIII 1000V
CATIV 600V
CATIII 1000V
CATIV 600V
CATIII 1000V
CATIV 600V
CATIII 1000V
CATIV 600V
CATIII 600V
CATIV 300V
CATIII 600V
CATIV 300V
Dimensions mm 280x88x50 248x85x45 248x85x45 248x85x45 232x85x45 225x65x46
Weight G 540 375 375 375 370 275

Product code 58749164

brand Fluke

State Новое

Manufacturer country США

Leave a request

Leave a request and our manager will contact you within an hour
callback
1
$settings->wid3get_name}
Emak Group

What can we offer you