Clamp meter, Fluke 381 - Fluke

Current clamps The new Fluke 381 clamp meter delivers all the features expected of a current clamp meter and allows the display to be removed for greater flexibility. Now one technician can perform tasks that previously required the participation of two. You can mount the Fluke 381 on a conductor, remove the display, move to another location to switch controls, or remove protective equipment, all the while seeing real-time readings. The new iFlex Flexible Current Probe (included) extends the measurement range to 2500 A ac and increases display flexibility, allows measurements on awkward sized conductors, and facilitates wire access....

Current clamps

The new Fluke 381 clamp meter delivers all the features expected of a current clamp meter and allows the display to be removed for greater flexibility. Now one technician can perform tasks that previously required the participation of two. You can mount the Fluke 381 on a conductor, remove the display, move to another location to switch controls, or remove protective equipment, all the while seeing real-time readings.

The new iFlex Flexible Current Probe (included) extends the measurement range to 2500 A ac and increases display flexibility, allows measurements on awkward sized conductors, and facilitates wire access.

Safety Compliance
EN/IEC 61010-1:2001; 1000V CAT III, 600V CAT IV

Electrical characteristics
AC current measurement with clamps
Range 999.9 A
Permission 0.1 A
Error 2% ± 5 digits (10-100Hz)
5% ± 5 digits (100-500Hz)
Form factor (50/60 Hz) 3 at 500 A
2.5 at 600 A
1.42 at 1000 A
Add 2% to account for crest factor > 2
AC current measurement with a flexible current probe
Range 999.9 A / 2500 A (45-500 Hz)
Permission 0.1 A / 1 A
Error 3% ± 5 units ml. res.
Form factor (50/60 Hz) 3.0 at 1100 A
, 2.5 at 1400 A
, 1.42 at 2500 A
Add 2% for crest factor > 2
Sensitivity
Distance from optimal position:
i2500-10 Flex i2500-18 Flex Error
A 0.5" (12.7mm) 1.4 in (35.6 mm) ±0.5%
B 0.8" (20.3mm) 2.0 in (50.8 mm) ±1.0%
C 1.4 in (35.6 mm) 2.5" (63.5 mm) ±2.0%
Measurement uncertainty implies finding the centralized primary conductor in an optimal position, the absence of an external electric and magnetic field, and maintaining the operating temperature.
D.C
Range 999.9 A
Permission 0.1 A
Error 2% ± 5 units ml. res.
AC voltage
Range 600V /1000V
Permission 0.1V / 1V
Error 1.5% + 5 digits (20-500Hz)
DC voltage
Range 600.0V / 1000V
Permission 0.1V / 1V
Error 1% ± 5 units ml. res.
Frequency measurement with clamps
Range 5.0-500.0 Hz
Permission 0.1 Hz
Error 0.5% ± 5 units ml. res.
Trigger sweep, level 5–10 Hz, ? 10 A
10–100 Hz, ? 5 A
100–500 Hz, ? 10 A
Frequency measurement with flexible current probe
Range 5.0-500.0 Hz
Permission 0.1 Hz
Error 0.5% ± 5 units ml. res.
Trigger sweep, level 5–20 Hz, ? 25 A
20–100 Hz, ? 20 A
100–500 Hz, ? 25 A
Resistance
Range 600 Ohm / 6 kOhm / 60 kOhm
Permission 0.1 ohm / 1 ohm / 10 ohm
Error 1% ± 5 units ml. res.
Mechanical characteristics
Size (L x W x H) 277 x 88 x 43 mm (55 mm remote)
Weight 350 g
Cheek opening width 34 mm
Flexible current probe diameter 7.5mm
Flexible current probe cable length
(from head to electronic connector)
1.8 m
Characteristics of the operating conditions
Working temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating Humidity Non-condensing (< 10 °C)
? 90% r.h. humidity (from 10 °C to 30 °C)
? 75% r.h. humidity (from 30 °C to 40 °C)
? 45% r.h. humidity (40°C to 50°C)
(no condensation)
Operating Altitude 2000 meters
Storage Altitude 12,000 meters
EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006
ETSI EN 300 489 V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID: T68-F381
RSS-210 IC: 6627A-F381
Temperature coefficients Add 0.1 x normalized error for each degree C above 28°C or below 18°C
Radio frequency 2.4GHz, ISM band, 10m distance
Safety Compliance ANSI/ISA S82.02.01:2004
CAN/CSA-C22.2 No. 61010-1-04
IEC/EN 61010-1:2001 up to 1000V CAT III, 600V CAT IV.
double insulation gap According to IEC 61010-2-032
Leakage on the surface of double insulation According to IEC 61010-1