Clamp meter, Fluke 381 - Fluke
Current clamps The new Fluke 381 clamp meter delivers all the features expected of a current clamp meter and allows the display to be removed for greater flexibility. Now one technician can perform tasks that previously required the participation of two. You can mount the Fluke 381 on a conductor, remove the display, move to another location to switch controls, or remove protective equipment, all the while seeing real-time readings. The new iFlex Flexible Current Probe (included) extends the measurement range to 2500 A ac and increases display flexibility, allows measurements on awkward sized conductors, and facilitates wire access....Current clamps
The new Fluke 381 clamp meter delivers all the features expected of a current clamp meter and allows the display to be removed for greater flexibility. Now one technician can perform tasks that previously required the participation of two. You can mount the Fluke 381 on a conductor, remove the display, move to another location to switch controls, or remove protective equipment, all the while seeing real-time readings.
The new iFlex Flexible Current Probe (included) extends the measurement range to 2500 A ac and increases display flexibility, allows measurements on awkward sized conductors, and facilitates wire access.
Safety Compliance
EN/IEC 61010-1:2001; 1000V CAT III, 600V CAT IV
Electrical characteristics | ||||
AC current measurement with clamps | ||||
Range | 999.9 A | |||
Permission | 0.1 A | |||
Error | 2% ± 5 digits (10-100Hz) 5% ± 5 digits (100-500Hz) | |||
Form factor (50/60 Hz) | 3 at 500 A 2.5 at 600 A 1.42 at 1000 A Add 2% to account for crest factor > 2 | |||
AC current measurement with a flexible current probe | ||||
Range | 999.9 A / 2500 A (45-500 Hz) | |||
Permission | 0.1 A / 1 A | |||
Error | 3% ± 5 units ml. res. | |||
Form factor (50/60 Hz) | 3.0 at 1100 A , 2.5 at 1400 A , 1.42 at 2500 A Add 2% for crest factor > 2 | |||
Sensitivity | ||||
Distance from optimal position: | ||||
i2500-10 Flex | i2500-18 Flex | Error | ||
A | 0.5" (12.7mm) | 1.4 in (35.6 mm) | ±0.5% | |
B | 0.8" (20.3mm) | 2.0 in (50.8 mm) | ±1.0% | |
C | 1.4 in (35.6 mm) | 2.5" (63.5 mm) | ±2.0% | |
Measurement uncertainty implies finding the centralized primary conductor in an optimal position, the absence of an external electric and magnetic field, and maintaining the operating temperature. | ||||
D.C | ||||
Range | 999.9 A | |||
Permission | 0.1 A | |||
Error | 2% ± 5 units ml. res. | |||
AC voltage | ||||
Range | 600V /1000V | |||
Permission | 0.1V / 1V | |||
Error | 1.5% + 5 digits (20-500Hz) | |||
DC voltage | ||||
Range | 600.0V / 1000V | |||
Permission | 0.1V / 1V | |||
Error | 1% ± 5 units ml. res. | |||
Frequency measurement with clamps | ||||
Range | 5.0-500.0 Hz | |||
Permission | 0.1 Hz | |||
Error | 0.5% ± 5 units ml. res. | |||
Trigger sweep, level | 5–10 Hz, ? 10 A 10–100 Hz, ? 5 A 100–500 Hz, ? 10 A | |||
Frequency measurement with flexible current probe | ||||
Range | 5.0-500.0 Hz | |||
Permission | 0.1 Hz | |||
Error | 0.5% ± 5 units ml. res. | |||
Trigger sweep, level | 5–20 Hz, ? 25 A 20–100 Hz, ? 20 A 100–500 Hz, ? 25 A | |||
Resistance | ||||
Range | 600 Ohm / 6 kOhm / 60 kOhm | |||
Permission | 0.1 ohm / 1 ohm / 10 ohm | |||
Error | 1% ± 5 units ml. res. | |||
Mechanical characteristics | ||||
Size (L x W x H) | 277 x 88 x 43 mm (55 mm remote) | |||
Weight | 350 g | |||
Cheek opening width | 34 mm | |||
Flexible current probe diameter | 7.5mm | |||
Flexible current probe cable length (from head to electronic connector) | 1.8 m | |||
Characteristics of the operating conditions | ||||
Working temperature | -10 °C to +50 °C | |||
Storage temperature | -40 °C to +60 °C | |||
Operating Humidity | Non-condensing (< 10 °C) ? 90% r.h. humidity (from 10 °C to 30 °C) ? 75% r.h. humidity (from 30 °C to 40 °C) ? 45% r.h. humidity (40°C to 50°C) (no condensation) | |||
Operating Altitude | 2000 meters | |||
Storage Altitude | 12,000 meters | |||
EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006 ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID: T68-F381 RSS-210 IC: 6627A-F381 | |||
Temperature coefficients | Add 0.1 x normalized error for each degree C above 28°C or below 18°C | |||
Radio frequency | 2.4GHz, ISM band, 10m distance | |||
Safety Compliance | ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001 up to 1000V CAT III, 600V CAT IV. | |||
double insulation gap | According to IEC 61010-2-032 | |||
Leakage on the surface of double insulation | According to IEC 61010-1 | |||
Departmental certificates |
Product code 58749166
brand Fluke
State Новое
Manufacturer country США