Article number:
58749167
Laser distance meter, Fluke 414D - Fluke
Laser rangefinder Attach the new Fluke 414D to your tool belt and take measurements beyond the capabilities of a conventional tape measure - up to 50 meters (165 feet). This professional laser distance meter is simple and easy to use, and guarantees increased accuracy and minimal measurement errors. You save time and money every day. 414D 419D 424D Distance measurement Nominal measurement error[1] ± 2.0 mm[3] ± 1.0 mm [3] Maximum measurement error[2] ± 3.0 mm[3] ± 2.0 mm[3] Distance to reflective plate Leica GZM26 50 m/ 165 ft 80 m / 260 ft 100 m/ 330 ft Typical range [1] 40 m/ 130 ft 80 m...Laser rangefinder
Attach the new Fluke 414D to your tool belt and take measurements beyond the capabilities of a conventional tape measure - up to 50 meters (165 feet). This professional laser distance meter is simple and easy to use, and guarantees increased accuracy and minimal measurement errors. You save time and money every day.414D | 419D | 424D | |
Distance measurement | |||
Nominal measurement error[1] | ± 2.0 mm[3] | ± 1.0 mm [3] | |
Maximum measurement error[2] | ± 3.0 mm[3] | ± 2.0 mm[3] | |
Distance to reflective plate Leica GZM26 | 50 m/ 165 ft | 80 m / 260 ft | 100 m/ 330 ft |
Typical range [1] | 40 m/ 130 ft | 80 m / 260 ft | 80 m / 260 ft |
Range in adverse conditions[4] | 35 m/ 115 ft | 60 m / 195 ft | 60 m / 195 ft |
Smallest display unit | 1 mm / 1/16 inch | 6 /30 / 60 mm (10 / 50 / 100 m) | |
? laser spot at a distance | 6 /30 / 60 mm (10 / 50 / 100 m) | 6 /30 / 60 mm (10 / 50 / 100 m) | |
Tilt measurement | |||
Measurement error by laser beam[5] | No | No | ± 0.2° |
Measurement error on the body of the device[5] | No | No | ± 0.2° |
Range | No | No | 360° |
General information | |||
Laser class | 2 | ||
Laser type | 635 nm, < 1 mW | ||
Protection class | IP40 | IP54 | |
Automatic laser shutdown | after 90 seconds | ||
Auto power off | after 180 seconds | ||
Type AAA, 2 x 1.5V NEDA 24A/IEC LR03 | Up to 3 000 measurements | Up to 5 000 measurements | |
Dimensions (H X W X D) | 116 mm (L) 53 mm (W) 33 mm (D) | 127 mm (L) 56 mm (W) 33 mm (D) | 127 mm (L) 56 mm (W) 33 mm (D) |
Weight (with batteries) | 113 | 153 | 158 |
Temperature range: Storage temperature | -25°C to +70°C (-13°F to +158°F) from 0 °C to +40 °C (from 32°F to +104°F) | -25°C to +70°C (-13°F to +158°F) -10 °C to +50 °C (from 14°F to +122°F) | |
Calibration cycle | Not applicable | Not applicable | Tilt and compass |
Max Height | 3000 m | 3000 m | 3000 m |
Permissible relative humidity | 85% at 20°F to 120°F ( -7°C to 50°C) | 85% at 20°F to 120°F ( -7°C to 50°C) | 85% at 20°F to 120°F ( -7°C to 50°C) |
Safety | IEC Standard No. 61010-1:2001 EN60825-1:2007 (Class II) | ||
Electromagnetic compatibility | EN 55022:2010 EN 61000-4-3:2010 EN 61000-4-8:2010 | ||
[1] Compliant at 100% target reflectance (white painted wall), low background light, 25°C. [2] Compliant at 10-500% target reflectance, high background light, temperature range -10°C to +50°C. [3] Uncertainties are observed in the range from 0.05 m to 10 m with an accuracy level of 95%. The maximum error may increase by 0.1 mm/m at distances from 10 m to 30 m and by 0.15 mm/m at distances over 30 m. [4] Compliant at 100% target reflectance and background illumination between 10,000 and 30,000 lux. [5] After user calibration. Additional relative angular deviation of ± 0.01° per degree up to ± 45° in each quadrant. At room temperature. For the entire operating temperature range, the maximum deviation increases by ± 0.1°. |
Product code 58749167
brand Fluke
State Новое
Manufacturer country США