Infrared and contact thermometers "Two in one" with an innovative display based on a graphic matrix.
With a menu-driven interface (available in 6 languages) operated by only three buttons, the Fluke 568 and 566 Digital Laser Thermometers make even the most difficult measurements much easier. The menu provides quick navigation with a simple push of a button to access additional functions such as setting emissivity, starting data logging, turning alarms on or off.
The Fluke 568 and 566 Two-in-One Infrared and Contact Thermometers are rugged and comfortable to use in harsh industrial environments for measuring electrical and mechanical equipment. These instruments have more features than conventional IR thermometers (or pyrometers), increasing efficiency and expanding the scope.
Product Features |
Infrared temperature range | 566: | -40°C to 650°C (-40°F to 1202°F) | 568: | -40°C to 800°C (-40°F to 1472°F) |
|
IR Measurement Accuracy | | < 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F); > 0 °C (32 °F): ± 1% or ± 1.0 °C (± 2.0 °F), whichever is greater |
|
Display resolution | |
IR Spectral Sensitivity | |
IR reaction time | |
Type K thermocouple inlet temperature range | | -270°C to 1372°C (-454°F to 2501°F) |
|
Type K thermocouple input accuracy | -270°C to -40°C: | ±(1°C + 0.2°/1°C) (-454°F to -40°F: ±(2°F + 0.2°/1°F)) | -40°C to 1372°C: | ±1% or 1°C (-40°F to 2501°F: ±1% or 2°F), whichever is greater |
|
D:S (Distance to spot size ratio) | |
laser pointer | | Point laser with output power < 1 mW, class 2 (II), wavelength from 630 to 670 nm |
|
Minimum spot size | |
Emissivity adjustment | | According to the built-in table for common materials or by setting a numerical value in the range from 0.10 to 1.00 in steps of 0.01 |
|
Saving data with a date and time stamp | 566: | 20 measurements | 568: | 99 measurement results |
|
Interface and cable for PC connection | 566: | Absent | 568: | USB 2.0 with FlukeView® Forms |
|
Hi/Low Alarm (Above/Below Limit) | | Sound and two-tone visual |
|
Display Min/Max/Avg/Diff values | |
Display | | 98 x 96 pixel graphic matrix with function menu |
|
Backlight | | Two-level - normal and high brightness for working in low light conditions |
|
Trigger lock | |
Switch between Celsius and Fahrenheit | |
Nutrition | 2.35833E+14 | 2 x AA/LR6 batteries | 2.36667E+14 | 2 AA/LR6 batteries or USB channel when used with PC |
|
Battery life | In continuous mode: | 12 hours with laser and backlight on; 100 hours with laser and backlight off |
|
Working temperature | | 0°C to 50°C (32°F to 122°F) |
|
Storage temperature | | -20°C to 60°C (-4°F to 140°F) |
|
Ball probe range with type K thermocouple | | -40°C to 260°C (-40°F to 500°F) |
|
Thermocouple Type K Ball Sensor Accuracy | | ± 1.1°C (2.0°F) 0°C to 260°C (32°F to 500°F), typically less than 1.1°C (2.0°F) from - 40°C to 0°C (-40°F to 32°F) |
|