  4. Documenting Calibrator, Fluke 754
Article number: 58749188

Documenting Calibrator, Fluke 754 - Fluke

Registering calibrator The Fluke 754 Multifunction Documenting Process Calibrator is a powerful, multifunctional documenting calibrator that allows you to download algorithms, lists, and instructions created with software, or send data to your computer for printing, archiving, and research. The 754 features an integrated HART® interface capable of performing nearly all everyday tasks that previously required a separate communicator. Features of the Fluke 754 Calibrator: Changes voltage (V), current (mA), RTD and thermocouple signals, frequency and resistance of sensors of testers, transmitters and other devices Excites/simulates...

Registering calibrator

The Fluke 754 Multifunction Documenting Process Calibrator is a powerful, multifunctional documenting calibrator that allows you to download algorithms, lists, and instructions created with software, or send data to your computer for printing, archiving, and research. The 754 features an integrated HART® interface capable of performing nearly all everyday tasks that previously required a separate communicator.

Features of the Fluke 754 Calibrator:

  • Changes voltage (V), current (mA), RTD and thermocouple signals, frequency and resistance of sensors of testers, transmitters and other devices
  • Excites/simulates voltage (V), current (mA), thermocouples, RTD signals, frequency, resistance, and pressure to calibrate transmitters
  • The power supply of the transducers during the test is carried out using a current loop with simultaneous measurement of the current strength
  • Measure/generate pressure with any of 29 Fluke 700Pxx modules
  • Creates and enforces "as-found/as-left" (measured/left) automated procedures to meet quality programs or requirements. Records and documents results
  • Up to one week saves loaded algorithms and calibration results.
  • Uses many features such as "autostep" (automatic step setting), settable unit, user input of values during the test, check of one and two-position switches, check of the square root value of differential pressure flow sensors, programmable measurement delay, etc. .
  • Easy to use
  • Three years warranty
  • Bright double white display. Simultaneously reads output and measured parameters.
  • Multilingual interface
  • Li-Ion battery for 10 hours of continuous use. Includes gas pressure gauge.
  • Work with short-pulse RTD transmitters and controllers with pulse length up to 1 ms.
  • Comes with demo version of DPC/Track software.
  • Compatible with many Asset Management software packages.

HART Capabilities

The Fluke 754 Multifunction Documenting Process Calibrator is designed to handle virtually all everyday tasks that would normally require a separate accessory device to connect to a separate communicator. In fact, it has the transmission capabilities of the Model 375 HART Communicator.

    • Requires no external box or second instrument for daily HART calibration and maintenance.
    • Has fast HART communication.
    • Supports popular HART transmitters with more device specific commands than any other HART calibrator.
    • Works with a group of master devices, in batch mode and with multipoint configuration.
    • Easily upgradeable as additional instruments are added and new HART versions are released.
    • Polls to determine device type, manufacturer, model, tags.
    • Reconfigures the configuration of the sensor distribution map for temperature sensors with two sensors.
    • Reads the basic HART PV variables and the output digital signal of the smart transmitter when measuring the analog current (mA) output.
    • Reads and writes HART configuration functions for field adjustment of PV ID tags, damping, and other top-level configuration settings.
    • Renames smart transmitters by reading and writing HART ID tags.
    Accuracy of measurements
    Constant pressure Range 1 year 2 years
    100,000 mV 0.02% + 0.005 mV 0.03% + 0.005 mV
    3.00000 V 0.02% + 0.00005 V 0.03% + 0.00005 V
    300000 V 0.02% + +0.0005 V 0.03% + 0.0005 V
    300.00 V 0.05% + +0.05 V 0.07% + 0.05V
    AC voltage Range Permission 1 year 2 years
    40 - 500 Hz
    3,000 V 0.001 V 0.5% + 0.002 V 1.0% + 0.004 V
    30.00 V 0.01V 0.5% + 0.02V 1.0% + 0.04V
    300.0 V 0.1 Hz 0.5% + 0.2V 1.0% + 0.2V
    D.C Range 1 year 2 years
    30,000 mA 0.01% + 5uA 0.015% + 7uA
    110.00 mA 0.01% + 20uA 0.015% + 30uA
    Resistance Range 1 year 2 years
    10,000 ohm 0.05% + 50mΩ 0.07% + 70mΩ
    100.00 ohm 0.05% + 50mΩ 0.07% + 70mΩ
    1.0000 kΩ 0.05% + 500mΩ 0.07% + 0.5 ohm
    10,000 kOhm 0.1% + 10 ohm 0.15% + +15 ohm
    Frequency Range Permission Accuracy (2 years)
    1.00 Hz to 110.00 Hz 0.01V 0.05 Hz
    110.1 Hz to 1100.0 Hz 0.1 Hz 0.5 Hz
    1.101 to 11.000 kHz 0.001 V 0.005 kHz
    11.01 to 50.00 kHz 0.01 V 0.05 Hz
    Simulation Accuracy (Excitation)
    Constant pressure Range 1 year 2 years
    100,000 mV 0.01% + 0.005 mV 0.015% + 0.005 mV
    1.00000 V 0.01% + 0.00005 V 0.015% + +0.0005V
    15.0000 V 0.01% + +0.0005V 0.015% + +0.0005 V
    D.C Range 1 year 2 years
    22,000 mA (Excitation) 0.01% + 0.003 mA 0.02% + 0.003 mA
    Current load (simulation) 0.02% + 0.007 mA 0.04% + 0.007 mA
    Resistance Range 1 year 2 years
    10,000 ohm 0.01% + 10mΩ 0.015% + 15mΩ
    100.00 ohm 0.01% + 20mΩ 0.015% + 30mΩ
    1.0000 kΩ 0.02% + 0.2 ohm 0.03% + 0.3 ohm
    10,000 kOhm 0.02% + 3 ohm 0.03% + 5 ohm
    Frequency Range 2 years
    0.1 Hz to 10.99 Hz 0.01 V
    0.01 Hz to 10.99 Hz 0.01V
    11.00 to 109.99 Hz 0.1 Hz
    110.0 to 1099.9 Hz 0.1 Hz
    1.100 to 21.999 kHz 0.002 kHz
    22.000 - 50.000 kHz 0.005 kHz
    Technical data
    Data recording and output functions Measurement functions: Voltage, current, resistance, frequency, temperature, pressure
    Reading speed: 1, 2, 5, 10, 20, 30, or 60 readings/minute
    Maximum record length: 8000 readings (7980 for 30 or 60 readings/minute)
    Ramp functions Excitation functions: Voltage, current, resistance, frequency, temperature
    Speed: 4 steps/second
    Route definition: Continuity and Voltage (Continuity detection is not possible with current excitation)
    Loop power function Voltage: Selectable, 26V
    Accuracy: 10%, 18V minimum at 22mA
    Maximum current: 25 mA, short circuit protected
    Maximum input voltage: 50 VDC
    Pitch Functions Excitation functions Voltage, current, resistance, frequency, temperature
    Manual steps Selectable steps, change with arrow buttons
    "Autostep" function (automatic step setting) Fully programmable functions, trigger delay, step value, step time, repeat
    Mechanical and general characteristics
    Dimensions 136 x 245 x 63 mm
    Weight 1.2 kg
    Batteries Built-in rechargeable Li-ion battery: 7.2V, 4400mAh, 30Wh
    Battery life usually >8 hours
    Replacing batteries Replace without opening the calibrator; no tools required.
    Side Port Connections Pressure module connector
    USB connector for connecting to your computer
    Digital instrument connector (HART)
    Connection for optional charger/rectifier
    Data storage capacity 1 week results of calibration procedures
    Specifications for 90 days The standard specification interval for the 750 series is 1 and 2 years.
    Typical, over 90 days, measurements and excitation accuracy can be assessed if
    Divide the "% Read" or "% Output" data obtained during one year by 2.
    Minimum data displayed as "% of full value" or
    "counts" or "ohms" remain unchanged.