Fluke 773 Low Current Clamp Multimeter - Fluke
Multimeter calibrator Purpose of the Fluke 773 Low Current Clamp Multimeter: Time-saving measurements of a 4-20 mA signal without breaking the current loop. How much time do you spend on the following activities? Making current measurements in mA by opening the wire and creating a break in the current loop Calling the control room to isolate the loop Checking analog input/output via remote control Troubleshooting devices through inputs and outputs for measuring low currents (mA) Repair of circuits with a current strength of 4 to 20 mA with irregular failures and malfunctions. Return to the workshop for additional tools....Multimeter calibrator
Purpose of the Fluke 773 Low Current Clamp Multimeter:
Time-saving measurements of a 4-20 mA signal without breaking the current loop.
How much time do you spend on the following activities?
- Making current measurements in mA by opening the wire and creating a break in the current loop
- Calling the control room to isolate the loop
- Checking analog input/output via remote control
- Troubleshooting devices through inputs and outputs for measuring low currents (mA)
- Repair of circuits with a current strength of 4 to 20 mA with irregular failures and malfunctions.
- Return to the workshop for additional tools.
If you're short on time on a busy day, pick up the Fluke 77X Low Current Clamp. They will allow you to save time and money by reducing the activities that you have to spend time on. Now you can troubleshoot 4mA to 20mA circuits without breaking the current loop or shutting down the system.
The Fluke 773 Low Current Clamp Multimeter features:
- Best in class 0.2% accuracy
- Resolution and sensitivity - about 0.01 mA
- Measurement of a signal from 4 to 20 mA without interrupting the current loop!
- Measurement of signals with low currents on PLC outputs and analog inputs / outputs of the control system
- Dual backlit display showing current measurement both in mA and as a percentage of the 4-20 mA range
- Built-in lamp for point illumination of conductors in places where external light does not penetrate
- Separate clamp with extension cable for measurements in hard-to-reach places
- Measurement of 10-50 mA signals in older control systems using the 99.9 mA range.
- Automatic change of 4-20 mA signal for remote testing
- Energy saving settings, auto power off, timed backlight off to prolong battery life
- The Hold function allows you to receive and display readings on the display when the measured values \u200b\u200bare not constant
- Measurement of 4-20 mA signals within a circuit
- Simultaneous measurement of low currents within a circuit with a 24 V power supply and test transducers
- Generation of 4-20 mA signals to test the inputs/outputs of control systems and I/P devices
- Low current ramp or low current output in 25% steps
- Automatic change of 4-20 mA signal for remote testing
- DC voltage measurement to test 24 V supply or I/O voltage signals
- DC voltage generation to test input devices accepting a 1-5V or 0-10V signal
- Measured low current signal output provides a constant low current signal corresponding to a 4 to 20 mA signal measured by a low current clamp: Allows low current signal to be recorded to a separate recorder without breaking the current loop; Low current output allows 4-20 mA current to be recorded to a data logging DMM or other device without breaking the current loop
- Low current I/O: Simultaneous measurement of a low current signal with a clamp and generation of a low current signal: Provides a low current input signal to the device and measures its output signal in the range of 4-20 mA for devices such as valves or low current isolators
- Voltage ramp or voltage output in 25% steps: Automatic voltage ramp for remote testing.
Parameter | Meaning | |
Characteristics of the operating conditions | ||
Measured conductor diameter | 4.5 mm, max | |
Working temperature | -10 to 50 °C | |
Storage temperature | -25 to 60 °C | |
Operating Humidity | < 90% at temp. less than 30 °C, < 75% at temp. 30 to 55°C | |
Operating Altitude | 0 to 2000 m | |
Degree of protection | IP40 | |
Size | 44x70x246mm | |
Weight | 410 g | |
Vibration | Random vibration with acceleration up to 2 g in the frequency range 5-500 Hz | |
Impact resistance: | Drop from a height of 1 m (without measuring clamp) | |
Electromagnetic Immunity (EMI), Radio Interference Immunity (RFI) | According to EN61326-1 Note: When measuring current with the test clamp, add 1mA to the reading for EM field strength from 1V/m to 3V/m. | |
Temperature coefficient | 0.01% °C ( 28°) | |
Battery Life | (4) AA 1.5 V alkaline, IEC LR6, 12 hours when generating mA at 500 ohms | |
Functional characteristics | ||
Measurement of low currents (measurement with clamps) | Range and Resolution | Accuracy |
0 - 20.99 mA 21.0 to 100.0 mA | 0.2% + 2 digits 1% + 5 digits | |
Low current measurements (measured sequentially with test sockets) | Range and resolution: 0 to 24.00 mA Accuracy: 0.2% + 2 digits | |
mA generation (Max. generation: 24 mA at 1000 ohms) | Range and resolution: 0 to 24.00 mA Accuracy: 0.2% + 2 digits | |
Current simulation in mA (Max. voltage 50 VDC) | Range and resolution: 0 to 24.00 mA Accuracy: 0.2% + 2 digits | |
Voltage generation (Max. generation current 2 mA) | Range and resolution: 0 - 10.00 V Accuracy: 0.2% + 2 digits | |
Voltage measurement | Range and resolution: 0 to 30.00 V Accuracy: 0.2% + 2 digits |
Product code 58749190
brand Fluke
State Новое
Manufacturer country США