Article number: 58749196

Digital multimeter, Fluke 87V - Fluke

Digital multimeter Accuracy and diagnostic features for maximum industrial performance The new Fluke 87 V-Series and 83 V-Series offer improved measurement performance, troubleshooting capabilities, increased accuracy and resolution to solve more problems in motor drives, industrial automation, power distribution systems and electro-mechanical equipment. The 80 Series V models are very similar in function to the classic 80 Series models, but with greater problem-solving capability, safety, convenience and impact protection. The new 80 Series V instruments have been independently tested to ANSI/ISA S82.01 2nd edition and EN61010-1...

Digital multimeter

Accuracy and diagnostic features for maximum industrial performance

The new Fluke 87 V-Series and 83 V-Series offer improved measurement performance, troubleshooting capabilities, increased accuracy and resolution to solve more problems in motor drives, industrial automation, power distribution systems and electro-mechanical equipment.

The 80 Series V models are very similar in function to the classic 80 Series models, but with greater problem-solving capability, safety, convenience and impact protection.

The new 80 Series V instruments have been independently tested to ANSI/ISA S82.01 2nd edition and EN61010-1 CAT IV 600V/CAT III 1000V standards. They can withstand surges up to 8,000 V and reduce the risks associated with surges and surges.

electrical safety
All inputs are protected to ANSI/ISA S82.01 and EN61010-1 CAT IV 600V and CAT III, 1000 V. They can withstand surges up to 8,000 V and reduce the risk of surges and surges.

Proper Measurement of Pulse Width Modulated Drive Signals
Until now, there has not been a multimeter capable of accurately measuring variable speed drives. And the new Fluke 87V is designed specifically for these complex signals. Think about the potential productivity you can get by eliminating the guesswork when troubleshooting a drive system. Every measurement is correct at every point in time.

  • Unique function to accurately measure the AC voltage of high-noise pulse-width modulation signals. Accurate measurement of variable speed drives and motor contacts
  • Accurate measurement of frequency (motor speed). Frequency measurement accuracy is not affected by the carrier frequency of the variable speed drive
  • Measure AC current with optional current clamp
  • Compare with 87V screen reading when measured on a variable speed drive
  • A special device blocks the strong high-frequency noise produced by powerful electric drive systems.
Characteristics
DC voltage
Max Voltage: 1000 V
Error: Fluke 83V: ±(0.1%+1)
Fluke 87V: ±(0.05%+1)
Maximum resolution: Fluke 83V: 100µV
Fluke 87V: 10µV
AC voltage
Max Voltage: 1000 V
Error: Fluke 83V: ±(0.5%+2)
Fluke 87V: ±(0.7%+2) True RMS
AC bandwidth Fluke 83 V: 5 kHz
Fluke 87 V: 20 kHz*
*with low pass filter; 3 dB @ 1 kHz
Maximum resolution: 0.1 mV
DC power
Maximum current: 10 A (20 A for 30 seconds maximum)
Current measurement error: Fluke 83V: ±(0.4%+2)
Fluke 87V: ±(0.2%+2)
Maximum resolution: Fluke 83V: 0.01 mA
Fluke 87 V: 0.01 µA
Alternating current
Maximum current: 10 A (20 A for 30 seconds maximum)
Current measurement error: Fluke 83V: ±(1.2%+2)
Fluke 87 V: ±(1.0%+2) True RMS
Maximum resolution: 0.1 uA
Resistance
Maximum resistance: 50M??
Error: Fluke 83V: ±(0.4%+1)
Fluke 87V: ±(0.2%+1)
Maximum resolution: 0.1??
Capacity
Maximum capacity 9.999uF
Error ±(1%+2)
Maximum Resolution 0.01 nF
Frequency
Maximum frequency 200 kHz
Error ±(0.005%+1)
Maximum Resolution 0.01 Hz
Fill factor
Fill factor 0.999
Error ±(0.2% per kHz +0.1%)
Maximum Resolution 0.001
Temperature measurements
Fluke 83 V, 87 V/E: -200.0°C - 1090°C
-328.0°F - 1994.0°F
sensors are supplied separately
Temperature probe 80 BK
-40.0°C - 260°C
-40.0°F - 500°F, 2.2°C or 2% whichever is greater
electrical conductivity
Maximum electrical conductivity 60.00 nS
Error ±(1.0%+10)
Maximum Resolution 0.01 nS
Diode testing
Range 3V
Permission: 1 mV
Error: ±(2% + 1)
Fill factor range
Error: ±(0.2% per kHz +0.1%)

Environmental conditions
Working temperature
-20°C to +55°C
Storage temperature
-40°C to +60°C
Humidity (non-condensing)
0% - 90% (0°C - 35°C)
0% - 70% (35°C - 55°C)
Operating Altitude
2000 m

General safety features
Over voltage category
from EN 61010-1 up to 1000V CAT III, 600V CAT IV
Approvals received
UL, CSA, T?V, VDE Listed

Mechanical and general characteristics
Size
201 x 98 x 52 mm (with case)
Weight
355 g
Weight with case and flexible holder
624 g
Display
Digital: 6000 samples with an update rate of 4 samples/sec.
(Model 87 also has 19999 counts in high resolution mode)
Analog: 32 segments, update rate 40 samples/sec
Frequency: 19,999 samples, update rate 3 samples/sec @ > 10 Hz.
Guarantee
Lifetime
Battery life
Alkaline: Typically about 400 hours without backlight.
blows
Drop from a height of one meter, which complies with IEC 61010-1:2001
Vibration
According to MIL-PRF-28800 for Class 2 instruments

Product code 58749196

brand Fluke

State Новое

Manufacturer country США

Leave a request

Leave a request and our manager will contact you within an hour