NYCY cable - STP
general information Cables of these brands prevent the interference of external magnetic waves and are intended for use in fixed laying, which ensures the transmission and distribution of electrical energy. NYCY / NYCY-fl / NYCY–LS N2XCY / N2XCY-fl / N2XCY–LS NAYCY / NAYCY-fl / NAYCY-LS NA2XCY / NA2XCY-fl / NA2XCY-LS DESIGN Conductive copper or aluminum single or stranded conductor of round or shaped shape PVC or XLPE insulation Belt PVC insulation Shield made of copper braid or wire PVC sheath (PET film under sheath) Production of conductive wires Type of conductive cores according to the number of wires...general information
Cables of these brands prevent the interference of external magnetic waves and are intended for use in fixed laying, which ensures the transmission and distribution of electrical energy.
NYCY / NYCY-fl / NYCY–LS
N2XCY / N2XCY-fl / N2XCY–LS
NAYCY / NAYCY-fl / NAYCY-LS
NA2XCY / NA2XCY-fl / NA2XCY-LS
DESIGN
- Conductive copper or aluminum single or stranded conductor of round or shaped shape
- PVC or XLPE insulation
- Belt PVC insulation
- Shield made of copper braid or wire
- PVC sheath (PET film under sheath)
Production of conductive wires
Type of conductive cores according to the number of wires forming them | Section, mm2 |
single wire | 1.5 / 10 / - |
stranded | 16 / 240 / 25 / 185 |
Cable specifications
Cable brand | Conductor cross section, mm2 | Approximate cable diameter, mm | Approximate cable weight, kg/km | Maximum electrical resistance of the conductive core at 20°С, Ohm/km, no more |
NYCY 1,0 kV | 2x4/4 2x6/6 2x10/10 2x16/16 3x4/4 3 x 6/6 3 x 10/10 3 x 16/16 3 x 25/16 3 x 35/16 3 x 50/25 3 x 70/35 3 x 95/50 3 x 120/70 3 x 150/70 3 x 185/95 3 x 240/120 4x4/4 4x6/6 4 x 10/10 4 x 16/16 4 x 25/16 4 x 35/16 4 x 50/25 4 x 70/35 4 x 95/50 4 x 120/70 4 x 150/70 4 x 185/95 4 x 240/120 5x4/4 5x6/6 5 x 10/10 | 15.5 16.5 19.0 21.0 17.0 18.5 20 22 25.5 27.5 31.0 35.0 39.5 43.5 47.5 52.0 59.5 17.5 19 21.0 23.5 29 31.0 35 40 45 50 55 62 69.0 19.0 20.5 22.5 | 350 440 610 820 407 510 700 980 1500 1930 2145 2890 3880 4840 5750 7290 9380 470 600 840 1190 1740 2190 2637 3571 4887 5951 7296 9133 11965 545 590 975 | 4.61 3.08 1.83 1.15 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 4.61 3.08 1.83 |
Cable specifications
Cable brand | Conductor cross section, mm2 | Approximate cable diameter, mm | Approximate cable weight, kg/km | Maximum electrical resistance of the conductive core at 20°С, Ohm/km, no more |
NYCY 1,0 kV | 2x4/4 2x6/6 2x10/10 2x16/16 3x4/4 3 x 6/6 3 x 10/10 3 x 16/16 3 x 25/16 3 x 35/16 3 x 50/25 3 x 70/35 3 x 95/50 3 x 120/70 3 x 150/70 3 x 185/95 3 x 240/120 4x4/4 4x6/6 4 x 10/10 4 x 16/16 4 x 25/16 4 x 35/16 4 x 50/25 4 x 70/35 4 x 95/50 4 x 120/70 4 x 150/70 4 x 185/95 4 x 240/120 5x4/4 5x6/6 5 x 10/10 | 15.5 16.5 19.0 21.0 17.0 18.5 20 22 25.5 27.5 31.0 35.0 39.5 43.5 47.5 52.0 59.5 17.5 19 21.0 23.5 29 31.0 35 40 45 50 55 62 69.0 19.0 20.5 22.5 | 350 440 610 820 407 510 700 980 1500 1930 2145 2890 3880 4840 5750 7290 9380 470 600 840 1190 1740 2190 2637 3571 4887 5951 7296 9133 11965 545 590 975 | 4.61 3.08 1.83 1.15 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 4.61 3.08 1.83 |
Cable specifications
Cable brand | Conductor cross section, mm2 | Estimated cable weight, kg/km | Maximum electrical resistance of the conductive core at 20°С, Ohm/km, no more |
NYCY | 7x1.5/2.5 8x1.5/2.5 10x1.5/2.5 12x1.5/2.5 14x1.5/2.5 16x1.5/2.5 19x1.5/4 21x1.5/6 24x1.5/6 30x1.5/6 40x1.5/10 52x1.5/10 61x1.5/10 | 350 400 410 470 520 620 660 790 850 1020 1280 1600 2000 | 12.1 |
7x2.5/2.5 8x2.5/2.5 10x2.5/4 12x2.5/4 14x2.5/6 16x2.5/6 19x2.5/6 21x2.5/6 24x2.5/10 30x2.5/10 40x2.5/10 52x2.5/10 61x2.5/10 | 450 510 600 660 750 800 940 1100 1150 1600 1660 2000 2280 | 7.41 | |
7x4/4 10x4/6 12x4/6 | 600 900 1060 | 4.61 | |
7x6/6 | 790 | 3.08 |
STP Cable Factory manufactures low voltage power cables and other sizes.
TECHNICAL SPECIFICATIONS
- Rated operating voltage - 0.6/1.0 kV
- Test voltage - 3.5 kV
- Permissible heating temperature of the cable core during operation: +70°C
- Relative humidity: 98%
Product code 90087946
brand STP