Cable N2XY-LS FE 180 - STP
general information Cable brand N2XY-LS FE 180 is used for transmission and distribution of electricity in case of fire (for power supply of fire safety circuits and fire extinguishing pumps, lighting of evacuation and emergency exits, evacuation elevators, air ventilation, explosive areas, operating blocks of hospitals). Cable brand N2XY-LS FE 180 is used for transmission and distribution of electricity in case of fire (for power supply of fire safety circuits and fire extinguishing pumps, lighting of evacuation and emergency exits, evacuation elevators, air ventilation, explosive areas, operating blocks of hospitals). The cable...general information
Cable brand N2XY-LS FE 180 is used for transmission and distribution of electricity in case of fire (for power supply of fire safety circuits and fire extinguishing pumps, lighting of evacuation and emergency exits, evacuation elevators, air ventilation, explosive areas, operating blocks of hospitals).
Cable brand N2XY-LS FE 180 is used for transmission and distribution of electricity in case of fire (for power supply of fire safety circuits and fire extinguishing pumps, lighting of evacuation and emergency exits, evacuation elevators, air ventilation, explosive areas, operating blocks of hospitals). The cable provides transmission and distribution of electricity in public places and residential buildings, as well as in computerized facilities equipped with microprocessor technology.
DESIGN
- Conductor
- Mica Tape Thermal Barrier
- XLPE insulation
- Interfacial filling with low fume and gas emission
- Glass tape thermal barrier
- PVC sheath with low smoke and gas emission
Cable properties
Conductor cross section, mm2 | Quantity and cross-section of current-carrying conductors pcs. x mm2 | Note |
1.5/10 RE | 2, 3, 4, 5 x 16-240 | Flame retardant halogen-free copper wire power cable with XLPE or flame retardant insulation and flame retardant sheath |
STP Cable Factory manufactures low voltage power cables and other sizes.
TECHNICAL SPECIFICATIONS
- Fire resistance time when exposed to an open flame: up to 90/180 minutes
- Maximum flame temperature: 1000°C
- Rated operating voltage - 0.66; 1.0; 3.0 kV
- With a large number of conductive wires, the cross section should not exceed 400 mm2.
- With an operating voltage of 0.66 kV, the cross section of the conductive wires should not exceed 50 mm2.
- Cable operating temperature: -50°C +50°C
- Relative humidity: 98%
- Service life: 25 years
Product code 90088007
brand STP