  1. Home
  2. Cable PPGng-HF
Article number: 90088065

Cable PPGng-HF - STP

general information Halogen-free cables of this brand are used for the transmission and distribution of electricity in the event of a fire (to provide power to fire safety circuits and fire extinguishing pumps, lighting evacuation and emergency exits, evacuation elevators, air ventilation, explosive areas, hospital operating blocks). PPGng-HF / PvPGng-HF / PBbPng-HF / PvBbPng-HF / PkbPng-HF / PvKbPng-HF / APPGng-HF / APvPGng-HF Halogen-free cables of this brand are used for the transmission and distribution of electricity in the event of a fire (to provide power to fire safety circuits and fire extinguishing pumps, lighting...

general information

Halogen-free cables of this brand are used for the transmission and distribution of electricity in the event of a fire (to provide power to fire safety circuits and fire extinguishing pumps, lighting evacuation and emergency exits, evacuation elevators, air ventilation, explosive areas, hospital operating blocks).

PPGng-HF / PvPGng-HF / PBbPng-HF / PvBbPng-HF / PkbPng-HF / PvKbPng-HF / APPGng-HF / APvPGng-HF

Halogen-free cables of this brand are used for the transmission and distribution of electricity in the event of a fire (to provide power to fire safety circuits and fire extinguishing pumps, lighting evacuation and emergency exits, evacuation elevators, air ventilation, explosive areas, hospital operating blocks). Cables provide transmission and distribution of electricity in public places and residential buildings, as well as in computerized facilities equipped with microprocessor technology.

DESIGN

  1. Conductor: Copper or aluminium.
  2. Insulation: Halogen-free polymer compound or XLPE.
  3. Inner sheath: Halogen-free polymer compound.
  4. Armor: The protective layer of cables, the marking of which ends with BbPng-HF, is formed by two galvanized steel tapes, and the protective layer of cables, the marking of which ends with KbPng-HF, consists of galvanized steel wire.
  5. Outer Sheath: Halogen-free polymer compound.

Cable specifications

Nominal cross section of conductors mm2 Quantity and section of current-carrying conductors, pcs. x mm2

1.5 / 240

1; 2; 3; 4 x 1.5/240

TECHNICAL SPECIFICATIONS

  • Rated operating voltage: 0.6; 1.0; 3.0 kV.
  • Number of cores: 1; 2; 3; 4; 5.
  • Operating temperature: -30°C +50°C
  • Relative humidity: 98%
  • Service life: 25 years