Cable KVBbShv (NYBY) - STP
general information Control cables of these brands are used for stationary laying in electrical devices, in AC devices with a rated voltage of 660V or in DC power distribution devices with a rated voltage of up to 1000V, in closed places, in channels and tunnels, in aggressive climatic conditions, in places subject to external mechanical influence. KVBbShv (NYBY) / KVBbShvng (NYBY-fl) / KVBbShvng – LS (NYBY-LS) / AKVBbShv (NAYBY) / AKVBbShvng (NAYBY-fl) / AKVBbShvng–LS, (NAYBY-LS) Control cables of these brands are used for stationary laying in electrical devices, in AC devices with a rated voltage of 660V or in DC power...general information
Control cables of these brands are used for stationary laying in electrical devices, in AC devices with a rated voltage of 660V or in DC power distribution devices with a rated voltage of up to 1000V, in closed places, in channels and tunnels, in aggressive climatic conditions, in places subject to external mechanical influence.
KVBbShv (NYBY) / KVBbShvng (NYBY-fl) / KVBbShvng – LS (NYBY-LS) / AKVBbShv (NAYBY) / AKVBbShvng (NAYBY-fl) / AKVBbShvng–LS, (NAYBY-LS)
Control cables of these brands are used for stationary laying in electrical devices, in AC devices with a rated voltage of 660V or in DC power distribution devices with a rated voltage of up to 1000V, in closed places, in channels and tunnels, in aggressive climatic conditions, in places subject to external mechanical influence.
The cores forming the cable are twisted in layers. The two strands in each layer must differ in color from each other and the other strands, or be numbered.
DESIGN
- Conductor made of copper or aluminum wires
- PVC insulation or flame retardant PVC with low fume and gas emission
- PVC belt insulation
- Armor made of two galvanized steel strips
- PVC sheath or flame retardant PVC with low fume and gas emission
Cable specifications
Wire brand | Conductor cross section, mm2 | Estimated wire weight, kg/km | Maximum electrical resistance of the conductive core at 20°С, Ohm/km, no more |
KVBbShv (NYBY) | 4 x 1.0 5 x 1.0 7 x 1.0 10 x 1.0 14 x 1.0 19 x 1.0 27 x 1.0 37 x 1.0 | 270 304 346 445 524 618 793 379 | 18.10 |
4 x 1.5 5 x 1.5 7 x 1.5 10 x 1.5 14 x 1.5 19x1.5 27 x 1.5 37 x 1.5 | 303 344 395 514 605 733 951 1210 | 12.10 | |
4x2.5 5x2.5 7x2.5 10x2.5 14x2.5 19x2.5 27x2.5 37x2.5 | 364 418 491 648 781 963 1292 1634 | 7.41 | |
4x4.0 5x4.0 7x4.0 10x4.0 | 467 545 651 865 | 4.61 | |
4x6.0 7 x 6.0 10x6.0 | 570 808 1099 | 3.08 |
TECHNICAL SPECIFICATIONS
- Rated operating voltage: 660V
- Conductor cross section, mm2: 0.75, 1.0, 1.5, 2.5, 4.0, 6.0, 10.0
- Number of cores: 2 to 61
- Relative humidity: 98%
- Cable operating temperature: -50°C +50°C
- Service life: underground and on overpasses - 15 years, in closed places, in channels and tunnels - 25 years