as@emakgroup.ae

Working hours of the company:

MON - FRI: from 9:00 to 18:00

Order a call
Close
  1. Home
  2. Cable accessories
  3. Single-core cables with cross-linked polyethylene (XLPE) insulation 6/35 kV
Article number: 90089247

Single-core cables with cross-linked polyethylene (XLPE) insulation 6/35 kV - Nexans

Single core high voltage cable with copper conductor, cross-linked polyethylene (XLPE) insulation, polyvinyl chloride (PVC) sheath Design: 1. Conductor - copper, stranded, round, sealed, conforms to class 2 IEC 60228 Cross-section of a stranded compacted core of a round shape 25/800 mm2 Cross-section of a stranded compacted core of a round shape, consisting of 5 sectors 1000/1600 mm2 2. Screen on the core - made of extruded semi-conductive cross-linked polyethylene 3. Insulation - cross-linked polyethylene (2X) Insulation screen - made of extruded semi-conductive cross-linked polyethylene 5. Separation layer - made of...

Single core high voltage cable with copper conductor, cross-linked polyethylene (XLPE) insulation, polyvinyl chloride (PVC) sheath

Design:

1. Conductor - copper, stranded, round, sealed, conforms to class 2 IEC 60228

  • Cross-section of a stranded compacted core of a round shape 25/800 mm2
  • Cross-section of a stranded compacted core of a round shape, consisting of 5 sectors 1000/1600 mm2

2. Screen on the core - made of extruded semi-conductive cross-linked polyethylene
3. Insulation - cross-linked polyethylene (2X)

  • Insulation screen - made of extruded semi-conductive cross-linked polyethylene

5. Separation layer - made of electrically conductive water-blocking tape
6. Screen made of copper wires fastened with copper tape (S)

Minimum shield cross-section for cables with core cross-section 25-120 mm2 - 16 mm2
Minimum shield cross-section for cables with core cross-section 150-300 mm2 - 25 mm2
Minimum shield cross section for cables with a core cross section of 400-1000 mm2 - 35 mm2
The minimum screen section for cables with a core section of 1200 mm2 and above is 50 mm2

Maximum screen section limits can be set based on customer requirements.

7. Separation layer - made of PET tape

Outer protective sheath - made of PVC (Y)

Specifications:

  • Core operating temperature / +900C
  • Maximum heating temperature of cable cores in case of failure / +1300C
  • Maximum heating temperature of cable cores in case of short circuit / +2500С
  • Short circuit duration (no more) / 5 sec.
  • Cable laying temperature (not less than) / -150С
  • Ambient temperature / -50 / +500C
  • Minimum cable bending radius / 15xD (D is cable outer diameter)

Product code 90089247

brand Nexans

Leave a request

Leave a request and our manager will contact you within an hour
callback
1
$settings->wid3get_name}
Emak Group

What can we offer you