PGK70 high voltage test unit - BAUR
The PGK70 unit is designed for high-voltage testing with direct and alternating current voltageThe PGK 70 HB test unit, consisting of two blocks, generates variable test voltages of alternating current of industrial frequency or direct current voltage of positive or negative polarity.
The operating unit, designed for a 19-inch equipment rack, has test voltage and leakage current indicators, safety elements and an adjustable transformer for voltage regulation.
The high-voltage unit contains a high-voltage transformer and, depending on the required operating mode, a rectifier or resistive rod. The polarity of the DC test voltage can be changed by changing the polarity in the high voltage unit rectifier.
Peculiarities:
- maintenance-free design
- adjustable output voltage
- ensuring operational safety
- short circuit protection by limiting the current inside the equipment
- voltage indication: dual-range analog device
- Current measurement: three-range analog device, decade switch
- overload protection
Mains power supply | 220 … 240 V |
Mains voltage frequency | 45 to 60 Hz |
Energy consumption | 640 VA |
Energy consumption in short circuit mode | 1200 VA |
Rated output voltage AC (RMS)/DC | 55 kV/70 kV |
Output AC current (RMS)/DC current | 7 mA/3 mA |
Short circuit current | 20 mA/12 mA |
Relative humidity | no condensation |
Ambient temperature range | working: 0 ... + 45? C |
storage interval: -20 … +60? C | |
High Voltage Meter Accuracy | 2.5% |
Milliammeter error | 2.5% |
Dimensions of the control unit housing (width × height × depth) | 502? 241? 290 mm |
Dimensions of the high-voltage unit (height/diameter) | 810 mm/385 mm |
Control unit weight | 13.5 kg |
Weight of high voltage unit | 36 kg |
Basic equipment:
- High voltage unit
- Control block
- Discharge rod, 12 kV
- Connecting cable installation-control module 5m
- Grounding cable, 3m
- High-voltage cable with clamps, 2.5 m
- Power cable
- Manual
Guarantee period 1 год