Viola high-voltage VLF installation - BAUR
High-voltage installation for testing 6-35 kV cables with cross-linked polyethylene insulation with voltages up to 60 kV at a frequency of 0.1 Hz.The high-voltage portable two-module VLF installation VIOLA is designed for:
- testing cables with cross-linked polyethylene insulation 6-35 kV with alternating voltage with a frequency of 0.1 Hz
- testing of cables with paper-oil insulation 6-10 kV with direct voltage up to 60 kV
- tests of cable sheaths with direct voltage up to 10 kV
- searching for damage to the cable sheath using the step voltage method together with a galvanometer.
The unit is easy to use: portable (thanks to its two-module design) and easy to connect. Tests can be carried out manually or fully automatically. The navigation menu on the built-in display is intuitive and fully Russified.
The functionality of the installation can be expanded by adding a diagnostic function for cable lines by measuring the dielectric loss tangent and measuring partial discharges in cables. Diagnostics allows you to assess the condition of cable lines with the identification of weak points and areas. It also becomes possible to use the MWT (Full Monitored Withstand Test) mode, which allows you to reduce cable testing time by simultaneously measuring loss tangent and partial discharges, thereby reducing the time stress on the cable with increased voltage.
Functional features of VIOLA:
- TrueSinus technology – pure sine wave regardless of load
- Automatic testing methods according to standards
- Maximum insulation capacitance up to 10 µF
- Fully automated, programmable test sequence
- Data transfer and storage via USB interface
- Short circuit protection
- Ease of transportation (two-module design)
- Diagnostic Reporter – application for processing and evaluating test reports
- Included in the State Register of Measuring Instruments of the Russian Federation
Technical characteristics of VIOLA :
Output voltage | |
VLF truesinus (VLF – sinusoidal) | 1…44 kVrms (62 kVp) |
VLF square wave voltage | 1…60 kV |
Constant pressure | ±1…60 kV |
Permission | 0.1 kV |
Accuracy | 1% |
Load range | 1 nF...10 µF |
Output current | |
Measuring range | 0…70 mA |
Permission | 1 µA |
Accuracy | 1 % |
Max. load | 0.85 µF at 0.1 Hz, 44 kV rms / 62 kV peak |
2.7 µF at 0.03 Hz, 44 kV rms / 62 kV peak | |
7.7 µF at 0.01 Hz, 44 kV rms / 62 kV peak | |
Frequency range | 0.01…0.1 Hz |
Common parameters | |
Supply voltage | 110…240 V, 50/60 Hz |
Max power consumption | 1400 W |
Data connector | USB 2.0 |
Languages: | Russian, German, English, Dutch, French, Spanish, Italian, Portuguese, Czech, Polish, Korean, Malay, Chinese (China), Chinese (Taiwan) |
Protection class | IP 24 |
Ambient temperature | -10…+50 °C |
Storage temperature | - 20...+60 °C |
High voltage unit | 505 x 503 x 405 mm |
Control block | 505 x 433 x 405 mm |
Are common | 505 x 854 x 405 mm |
Weight (two parts) | 19 kg / 57 kg |
Basic equipment VIOLA:
- High-voltage VLF test setup VIOLA
- High voltage test cable - 10 m (non-removable)
- Grounding rod and removing residual voltage.
- Ground cable
- Shunt plug for external emergency shutdown
- G-clamp, 45 mm
- Power cable
- Diagnostic Reporter (on USB flash drive)
- Manual
- Quick Guide
Additional accessories and options:
? External emergency stop device with warning lamps, cable length 25 or 50 m
? Discharge and grounding rod GDR 80-272
? Transport trolley
? Portable PD diagnostic system PD-TaD 62
? Remote control via BAUR software:
– Laptop with installed software (Windows OS and BAUR 4 software), including laptop bag
– USB 2.0 cable, 3 m
Software functions offered as options*
– Interface for geographic information systems
– BAUR GeoBase Map (list of suggested countries available on request)
– Installation in the office (BAUR 4 software for office PC)
– Cable testing
– PD measurement (partial discharge measurement)
*Module depending on system configuration
Guarantee period 1 год